Burn-in test of semi-finished products:

course of action

before glue-irrigating, all modules will be inspecte by QC, 
and the good ones will be under burn-in test for 48 hours.

Aim:

Completely check the performance of every electronic component, 
eliminate the risk of concealed defect,so that to make sure delivering excellence to customers

Burn-in test of finished products:

Course of action

after fixing the modules on cabinets, all of the cabinets will be pieced up and lighted up 
for 48hours to mimic the authentic installation and application, 

Aim:

100% guarantee no dark point, poor soldering...etc; make sure the accurate size of each 
cabinet to get high uniformity led displays

Ingress protection test

Course of action

Since the ingress protection plays an important role in the quality of outdoor led display, 
Topvision does the highpress flushing test on each cabinet, in addition to sinking, water
 spray tests, make sure each cabinet is good enough at waterproof and dustproof

Aim:

make sure the cabinet airtightness meets IP65

Corrosion test

Course of action

Salt spray test on every cabinet during the production

Aim:

make sure the PCB, casing can work under high uniformity and salty enviroment, 
easpecailly in the coast

Adjustment and Calibration in stimulated authentic environment

Course of action

all outdoor led displays will be palce outdoor in similar final working
 environments before shipments

Aim:

confirm customers what they get will be exactly what they are looking for,
 and out of their expectation

Vibration test

mimic the vibration working enviroment of traffic led display (VMS),
 mobile led display

Aim:

make sure the products are anti-vibration, and can work under such conditions